VIGO SYSTEM S.A.

Products

PCI-2TE



2-13 μm IR PHOTOCONDUCTORS THERMOELECTRICALLY COOLED OPTICALLY IMMERSED

Description

The PCI-2TE-λopt photodetectors series (λopt - optimal wavelength in micrometers) feature two-stage thermoelectrical cooler IR photoconductive detector, optically immersed to high refractive index GaAs hyperhemispherical (standard) or hemispherical or any intermediate lens (as option) for different acceptance angle and saturation level.

The devices are optimized for the maximum performance at λopt. Cut-on wavelength is limited by GaAs transmittance (~0.9 µm). Bias is needed to operate photocurrent. Performance at low frequencies (<20 kHz) is reduced due to 1/f noise. Highest performance and stability are achieved by application of variable gap (HgCd)Te semiconductor, optimized doping and sophisticated surface processing.

Custom devices with quadrant cells, multielement arrays, different windows, lenses and optical filters are available upon request.

Standard detectors are available in TO8 packages with wAl2O3 or wZnSeAR windows. Other packages, windows and connectors are also available.

 

  • High performance in the 2 to 13 µm spectral range
  • Fast response
  • Convenient to use
  • Wide dynamic range
  • Compact, rugged and reliable
  • Low cost
  • Prompt delivery
  • Custom design upon request
Parameter
Symbol
Unit
PCI-2TE-4
PCI-2TE-5
PCI-2TE-6
PCI-2TE-9
PCI-2TE-10.6
PCI-2TE-12
PCI-2TE-13
Optimal Wavelength
λopt
µm
4
5
6
9
10.6
12
13
Detectivity*):
@ λpeak, 20kHz
@ λopt, 20kHz
D*
cm⋅Hz1/2⋅W-1
 
≥6.0×1010
≥4.0×1010
 
≥4.0×1010
≥2.0×1010
 
≥2.0×1010
≥1.0×1010
 
≥1.0×1010
≥4.0×109
 
≥3.5×109
≥1.4×109
 
≥1.0×109
≥4.5×108
 
≥4.0×108
≥2.3×108
Voltage Responsivity -
Width Product
@ λopt, 1×1mm
Rv⋅w
V⋅mm⋅W-1
≥6000
≥3000
≥600
≥40
≥15
≥5
≥2.5
Time Constant
τ
ns
≤4000
≤2000
≤1000
≤20
≤10
≤2
≤2
1/f Corner Frequency
1/f
kHz
1 to 20
Bias Current - Width Ratio
Ib⋅w-1
mA⋅mm-1
0.05 to 0.3
0.1 to 0.5
0.3 to 0.8
2 to 5
5 to 20
Sheet Resistance
Rsq
Ω
600 to 1500
300 to 500
200 to 600
80 to 200
50 to 150
60 to 100
40 to 120
Operating Temperature
T
K
~230
Acceptance Angle, F/#
Φ, -
deg, -
36, 1.62

*) Data sheet states minimum guaranteed D* values for each detector model. Higher performance detectors can be provided upon request.

Type
Optical Area [mm×mm]
0.025×0.025
0.05×0.05
0.1×0.1
0.2×0.2
0.25×0.25
0.5×0.5
1×1
2×2
3×3
4×4
PCI-2TE-4
 
 
 
 
X
X
X
X
 
 
PCI-2TE-5
 
 
 
 
X
X
X
X
 
 
PCI-2TE-6
 
 
 
 
X
X
X
X
 
 
PCI-2TE-9
 
 
 
 
X
X
X
X
 
 
PCI-2TE-10.6
 
 
 
 
X
X
X
X
 
 
PCI-2TE-12
 
 
 
 
X
X
X
X
 
 
PCI-2TE-13
 
 
 
 
X
X
X
X
 
 
 

x - standard detectors