The VPDC and VPAC is the DC or AC coupled transimpedance preamplifiers. The Parameters of preamlifiers are optimized for 3 approximated detector resistance ranges. When is less than 100 Ω, between 100 Ω and 10 kΩ, more than 5 kΩ.
Device is closed in stand alone enclosure or integrated inside heat sink with detector.
|
RD≤ 100 Ω |
||||
|
Model |
Bandwidth |
Transimp. |
Eq. Input Noise |
CD max |
|
VPAC 0.1 |
0.1 |
100 |
5 |
1000 |
|
VPAC 0.3 |
0.3 |
100 |
5 |
1000 |
|
VPAC 1 |
1 |
100 |
5 |
1000 |
|
VPAC 5 |
5 |
24 |
6.5 |
250 |
|
VPAC 10 |
10 |
10 |
7 |
100 |
|
VPAC 20 |
20 |
5 |
8 |
50 |
|
VPAC 50 |
50 |
5 |
10 |
25 |
|
VPAC 100 |
100 |
5 |
10 |
10 |
|
VPAC 250 |
250 |
5 |
10 |
5 |
|
100 Ω ≥ RD≤ 10 KΩ |
||||
|
Model |
Bandwidth |
Transimp. |
Eq. Input Noise |
CD max |
|
VPAC 0.1 |
0.1 |
100 |
3 |
1000 |
|
VPAC 0.3 |
0.3 |
100 |
3 |
1000 |
|
VPAC 1 |
1 |
100 |
3 |
1000 |
|
VPAC 5 |
5 |
50 |
3.5 |
250 |
|
VPAC 10 |
10 |
30 |
4 |
100 |
|
VPAC 20 |
20 |
20 |
4 |
50 |
|
VPAC 50 |
50 |
10 |
4.5 |
25 |
|
VPAC 100 |
100 |
10 |
5 |
10 |
|
VPAC 250 |
250 |
10 |
5 |
5 |
|
RD≥ 5 KΩ |
||||
|
Model |
Bandwidth |
Transimp. |
Eq. Input Noise |
CD max |
|
VPAC 0.1 |
0.1 |
1000 |
0.3 |
100 |
|
VPAC 0.3 |
0.3 |
1000 |
0.3 |
100 |
|
VPAC 1 |
1 |
1000 |
0.5 |
50 |
|
VPAC 5 |
5 |
300 |
0.6 |
20 |
|
VPAC 10 |
10 |
200 |
0.8 |
15 |
|
VPAC 20 |
20 |
100 |
1 |
8 |
|
VPAC 50 |
50 |
|||
|
VPAC 100 |
100 |
|||
|
VPAC 250 |
250 |
|||
|
More info |
|